Specification Parameter Table (@1200g/mm grating)
Omni-λ300i Series | |
Focal length (mm) | 320 |
relative aperture | F/4.2 |
optical structure | C-T |
Scanning step (nm) | 0.005 |
stray light | 1X10-5 |
Focal plane (mm) | 30 (w)X14 (h) |
Optical axis height (mm) | 146 |
Grating specifications mm | 68X68 |
encoder table | Triple Grating |
Slit specifications | Slit width 0.01-3mm continuously manually adjustable, with optional automatic slit. Slit height: 2, 4, 14mm optional. |
Overall dimensions (mm) | 420X295X232 |
Weight (Kg) | 16 |
power wastage | 100W peak @ 24V |
communication interface | USB2.0 standard, RS-232 optional |
Omni-λ300i Series "King of Image Spectra" Grating SpectrometerSpecification Sheet@Various Gratings
Grating (g/mm) | 2400 | 1800 | 1200 | 600 | 300 | 150 | 75 |
Inverted line dispersion (nm/mm)
@435.83nm |
0.91 |
1.39 |
2.29 |
4.87 |
9.97 |
20.13 |
40.43 |
Mechanical scanning range (nm) | 0-600 | 0-800 | 0-1200 | 0-2400 | 0-4800 | 0-9600 | 0-19200 |
Scanning step (nm) | 0.0025 | 0.0035 | 0.005 | 0.01 | 0.02 | 0.04 | 0.08 |
Spectral resolution (nm)
@ PMT |
0.04 |
0.06 |
0.08 |
0.16 |
0.32 |
0.64 |
1.28 |
Spectral resolution (nm)
@CCD (15um) |
0.069 |
0.105 |
0.173 |
0.368 |
0.754 |
1.52 |
3.05 |
CCD single shot spectral range (nm)
@30mmCCD |
27.6 |
41.7 |
68.7 |
146.1 |
299.1 |
603.9 |
1212.9 |
Wavelength accuracy (nm) | ±0.1 | ±0.14 | ±0.2 | ±0.4 | ±0.8 | ±1.6 | ±3.2 |
Wavelength repeatability (nm) | 0.015 | 0.02 | 0.025 | 0.05 | 0.1 | 0.4 | 0.8 |
Note 1: The test condition for resolution is the center wavelength of 435.83 nm;
Note 2: CCD single-time spectral range, inverted line dispersion for the center wavelength of 435.83nm under the typical value, with the center wavelength increases, the spectral range becomes narrower;
Note 3: As the center wavelength increases, the value of the inverted line dispersion decreases, and as the center wavelength decreases, the value of the inverted line dispersion increases.
Typical Model List
model number | descriptive |
Omni-λ3004i | 320mm focal length image-corrected spectrometer with side entry, dual CCD exit, and simultaneous installation of three gratings |
Omni-λ3005i | 320mm focal length image-corrected spectrometer with side entrance, straight slit exit, and simultaneous installation of three gratings |
Omni-λ3006i | 320mm focal length image-corrected spectrometer with side entry, direct CCD exit, and simultaneous installation of three gratings |
Omni-λ3007i | Image-corrected spectrometer with 320mm focal length, side entrance, double slit exit, three gratings can be installed at the same time |
Omni-λ3008i | 320mm focal length image-corrected spectrometer, side entrance, CCD direct exit, slit side exit, three gratings can be installed at the same time |
Omni-λ3015i | 320mm focal length image-corrected spectrometer, side entrance, straight slit exit, three gratings can be installed simultaneously, infrared coating |
Omni-λ3017i | 320mm focal length image-corrected spectrometer, side entry, slit double exit, three gratings can be installed at the same time, infrared coating |
Omni-λ3024i | 320mm focal length image-corrected spectrometer with dual inlets, dual CCD outlets, three gratings can be installed simultaneously |
Omni-λ3027i | 320mm focal length image-corrected spectrometer with dual inlets, dual slit outlets, and the ability to install three gratings simultaneously |
Omni-λ3028i | 320mm focal length image-corrected spectrometer with dual inlets, direct CCD exit, slit side exit, and simultaneous installation of three gratings |
Omni-λ3047i | 320mm focal length image-corrected spectrometer, side entrance, double slit exit, three gratings simultaneously, UV coating |
Omni-λ3048i | 320mm focal length image-corrected spectrometer, side entrance, CCD direct exit, slit side exit, three gratings can be installed at the same time, UV-coated |
Note 1: For this model series, the slit is manual (motorized slit is an additional option);
Note 2: This model series, need additional optional grating, * can be configured with a maximum of 3 pieces of grating;
Note 3: This model series, does not include CCD interface flange, filter wheel, shutter, these accessories need to be selected additionally;
Note 4: For more configuration models, please consult our relevant sales.
Typical spectrometer Omni-λ3028i form factor drawing:
Omni-λ300i Entrance
Omni-λ300i outlet
Note: Where blue labeled are standing stock grating, it is recommended to prioritize the choice
Model | Range(nm) | Grooves (g/mm) | Blaze (nm) | Size(mm) |
Holographic |
|
|
|
|
1-360-180-500-NP | 180-400 | 3600 | 300 | 68 x 68 |
1-240-250-600-NP | 250-600 | 2400 | 300 | 68 x 68 |
1-240-190-800-NP | 190-600 | 2400 | 250 | 68 x 68 |
1-200-300-900-NP | 300-720 | 2000 | 475 | 68 x 68 |
1-180-350-900-NP | 350-800 | 1800 | 500 | 68 x 68 |
1-180-190-900-NP | 190-800 | 1800 | 250 | 68 x 68 |
1-120-190-800-NP | 190-800 | 1201.6 | 250 | 68 x 68 |
1-120-400-1200-NP | 400-1200 | 1200 | 700 | 68 x 68 |
Ruled |
|
|
|
|
1-240-240-NP | 190-600 | 2400 | 240 | 68 x 68 |
1-240-300-NP | 250-600 | 2400 | 300 | 68 x 68 |
1-180-400-NP | 300-800 | 1800 | 400 | 68 x 68 |
1-180-500-NP | 350-800 | 1800 | 500 | 68 x 68 |
1-120-250-NP | 200-500 | 1200 | 250 | 68 x 68 |
1-120-300-NP | 200-600 | 1200 | 300 | 68 x 68 |
1-120-400-NP | 200-1000 | 1200 | 400 | 68 x 68 |
1-120-500-NP | 350-1100 | 1200 | 500 | 68 x 68 |
1-120-750-NP | 500-1200 | 1200 | 750 | 68 x 68 |
1-090-550-NP | 350-1600 | 900 | 550 | 68 x 68 |
1-083-1200-NP | 700-1700 | 830 | 1200 | 68 x 68 |
1-060-300-NP | 200-600 | 600 | 300 | 68 x 68 |
1-060-500-NP | 330-1000 | 600 | 500 | 68 x 68 |
1-060-750-NP | 500-1500 | 600 | 750 | 68 x 68 |
1-060-1000-NP | 650-2200 | 600 | 1.0 µm | 68 x 68 |
1-060-1200-NP | 800-2400 | 600 | 1.2 µm | 68 x 68 |
1-060-1600-NP | 1-2.4 µm | 600 | 1.6 µm | 68 x 68 |
1-030-300-NP | 200-600 | 300 | 300 | 68 x 68 |
1-030-500-NP | 300-1000 | 300 | 500 | 68 x 68 |
1-030-760-NP | 450-1500 | 300 | 760 | 68 x 68 |
1-030-1000-NP | 600-2000 | 300 | 1000 | 68 x 68 |
1-030-1200-NP | 800-2200 | 300 | 1200 | 68 x 68 |
1-030-2000-NP | 1.4-4 µm | 300 | 2.0 µm | 68 x 68 |
1-030-3000-NP | 2-4.8 µm | 300 | 3.0 µm | 68 x 68 |
1-015-300-NP | 200-600 | 150 | 300 | 68 x 68 |
1-015-500-NP | 330-1100 | 150 | 500 | 68 x 68 |
1-015-800-NP | 400-1600 | 150 | 800 | 68 x 68 |
1-015-1000-NP | 600-2000 | 150 | 1090 | 68 x 68 |
1-015-1250-NP | 800-2500 | 150 | 1250 | 68 x 68 |
1-015-2000-NP | 1.1-4 µm | 150 | 2 µm | 68 x 68 |
1-015-3000-NP | 2.2-6 µm | 150 | 3 µm | 68 x 68 |
1-015-4000-NP | 2.5-8 µm | 150 | 4 µm | 68 x 68 |
1-0075-8000-NP | 6-16 µm | 75 | 8 µm | 68 x 68 |
1-0075-10000-NP | 6-18 µm | 75 | 10 µm | 68 x 68 |
1-0075-12000-NP | 9-20 µm | 75 | 12.0 µm | 68 x 68 |
1-0050-12000-NP | 8-22 µm | 50 | 12 µm | 68 x 68 |
Grating specification model table 2: Economy grating (this series applies to Omni-λ300i, Omni-λ500i, Omni-λ750i and other series of spectrometers)
Note: Where the blue labeled are standing stock grating, it is recommended that the priority choice
model number | Range of use (nm) | Raster engraving (g/mm) | Flash wavelength (nm) | Specification size (mm) |
Scribing encoder |
|
|
|
|
1-180-500 | 350-800 | 1800 | 500 | 68 x 68 |
1-120-300 | 200-600 | 1200 | 300 | 68 x 68 |
1-120-500 | 350-1000 | 1200 | 500 | 68 x 68 |
1-120-750 | 500-1200 | 1200 | 750 | 68 x 68 |
1-060-300 | 200-600 | 600 | 300 | 68 x 68 |
1-060-500 | 330-1000 | 600 | 500 | 68 x 68 |
1-060-750 | 500-1500 | 600 | 750 | 68 x 68 |
1-060-1000 | 650-2200 | 600 | 1000 | 68 x 68 |
1-060-1250 | 800-2400 | 600 | 1250 | 68 x 68 |
1-060-1600 | 1-2.4um | 600 | 1600 | 68 x 68 |
1-030-500 | 300-1000 | 300 | 500 | 68 x 68 |
1-030-750 | 450-1500 | 300 | 750 | 68 x 68 |
1-030-1000 | 600-2000 | 300 | 1000 | 68 x 68 |
1-030-1250 | 850-2500 | 300 | 1250 | 68 x 68 |
1-030-1800 | 1.2-3.6um | 300 | 1800 | 68 x 68 |
1-030-2000 | 1.4-4um | 300 | 2000 | 68 x 68 |
1-030-3000 | 2-4.8um | 300 | 3000 | 68 x 68 |
1-015-500 | 350-1000 | 150 | 500 | 68 x 68 |
1-015-4000 | 2.5-8um | 150 | 4000 | 68 x 68 |
Typical Grating Efficiency Curves